Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

8A2B Proline Promass A 200 科里奥利流量计

8A2B Proline Promass A 200 科里奥利流量计

200 科里奥利流量计

The compact Promass A is ideal for continuous process control in demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow rates and high pressure. With its cost-effective genuine loop-powered technology and intrinsically safe design (Ex ia), Promass A 200 offers highest operational safety in hazardous areas. Heartbeat Technology ensures safe processes.
Compare

Density/Concentration

Measuring Principle Coriolis
Product headline Genuine loop-powered flowmeter for accurate measurement of lowest flow rates.
Suitable for applications with smallest flow quantities in the chemical industry.
Sensor features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. process pressure 430.9 bar (6250 psi)
Medium temperature range -50 to 205 °C (-58 to 401 °F)
Ambient temperature range -40 to 60 °C (-40 to +140 °F)
Sensor housing material Stainless steel, 1.4404 (316L)
Transmitter housing material Stainless steel, CF-3M (316L, 1.4404)
AlSi10MG, coated
Degree of protection IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex, KC
Product safety CE, C-TICK
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, cGMP

Gas

Measuring Principle Coriolis
Product headline Genuine loop-powered flowmeter for accurate measurement of lowest flow rates.
Suitable for applications with smallest flow quantities in the chemical industry.
Sensor features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. process pressure 430.9 bar (6250 psi)
Medium temperature range -50 to 205 °C (-58 to 401 °F)
Ambient temperature range -40 to 60 °C (-40 to +140 °F)
Sensor housing material Stainless steel, 1.4404 (316L)
Transmitter housing material Stainless steel, CF-3M (316L, 1.4404)
AlSi10MG, coated
Degree of protection IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex, KC
Product safety CE, C-TICK
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, cGMP

Liquids

Measuring Principle Coriolis
Product headline Genuine loop-powered flowmeter for accurate measurement of lowest flow rates.
Suitable for applications with smallest flow quantities in the chemical industry.
Sensor features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. process pressure 430.9 bar (6250 psi)
Medium temperature range -50 to 205 °C (-58 to 401 °F)
Ambient temperature range -40 to 60 °C (-40 to +140 °F)
Sensor housing material Stainless steel, 1.4404 (316L)
Transmitter housing material Stainless steel, CF-3M (316L, 1.4404)
AlSi10MG, coated
Degree of protection IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex, KC
Product safety CE, C-TICK
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, cGMP

Proline Promass A 200
Coriolis flowmeter
True loop-powered flowmeter for precise measurement of the lowest flow rates
Advantages
Space-saving installation – compact, lightweight sensor

Highest product quality – self-draining measuring tube design for all pipe sizes

Optimum process safety – resistant to corrosive environmental conditions and internal clogging

Convenient device wiring – separate connection compartment

Safe operation – no need to open the device thanks to the display with touch control and background lighting

Integrated verification – Heartbeat Technology
Field of application
The compact Promass A is ideal for continuous process control in demanding applications. Its unique self-draining single-tube system enables accurate measurement of liquids and gases at the lowest flow rates and high pressures. The Promass A 200 uses cost-effective, genuine loop-powered technology and intrinsically safe design (Ex ia), providing the highest operational safety in explosion-protected areas. Heartbeat Technology enables safe processes.

The measuring principle is unaffected by fluid properties such as viscosity or density

Suitable for applications with the lowest flow rates in the chemical industry.

Device properties

Nominal diameter: DN 1 to 4 (1/24 to 1/8”)

Process pressure up to 430.9 bar (6250 psi)

Medium temperature up to +205 °C (+401 °F)

Loop-powered technology

Robust two-compartment housing

Plant safety: global certifications (SIL, hazardous area)

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

 

Source:Endress+Hauserpublic information from the website

市政污水处理

市政污水处理污水处理厂 · 质量流量计应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 质量流量计应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 质量流量计应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 质量流量计应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。