高精度雷达液位计
Technical Data
CompareContinuous / Liquids
| Measuring Principle | |
| Supply / Communication | 4-wire (HART) |
| Frequency | C-band (~6 GHz) |
| Accuracy | +/- 1 mm |
| Ambient temperature | Standard: -40 °C ... 80 °C (-40 °F ... 176 °F) For calibration to regulatory standards: -25 °C ... 60 °C (-13 °F ... 131 °F) |
| Process temperature | -40 °C ... 200 °C (-40 °F ... 392 °F) |
| Process pressure / max. overpressure limit | Vacuum ... 64 bar (Vacuum ... 580 psi) |
| Main wetted parts | 316Ti |
| Process connection | DN150 ... DN250 /3" ... 10" |
| Communication | 4 ... 20 mA HART |
| Certificates / Approvals | ATEX, FM, CSA, IEC Ex, NEPSI |
| Safety approvals | Overfill prevention WHG |
| Marine approval | GL/ ABS |
Micropilot FMR530 is suitable for non-contact precision measurement of oil tank levels and can also be used for custody transfer measurement. FMR530 meets the relevant requirements of OIML R85 and API 3.1B. FMR530 uses four-wire technology with HART and 24 V DC intrinsically safe power supply, economical and easy to install.
Benefits
Accuracy: 0.5 mm (2σ value)
Custody transfer applications certified at national level (NMi and PTB)
The device can be used standalone or integrated into a tank level measurement system via the NRF590 tank-side indicator
Simple on-site operation via a menu-driven alphanumeric display module
FDT/DTM (FieldCare) software for convenient device commissioning, documentation and fault diagnostics
Antenna selected according to the application. Conical stilling wells are suitable for direct installation of the flat-face antenna
All antennas use a gas-tight process connection as standard (double safety)
Application
When the tank or nozzle geometry is not suitable for a parabolic antenna, a horn antenna can be used for free-space measurement (up to 25 m).
Process connection: flange
Temperature range: -40 to +200°C (-40 to +392°F)
Pressure range: -1 to +64 bar (-14.5 to +928 psi)
Maximum measuring range: 25 m (82 ft)
Accuracy: less than ±1 mm
C-band: 6 GHz
International explosion protection approval, custody transfer approval, WHG overflow protection, SIL, marine approval
E+H Product Configurator
Please enter the product model to configure
Product Comparison
Please enter the product models to compare in the fields below. Up to three products can be compared
Technical Documentation
Technical Specifications
Documents/Manuals/Software
Accessories/Spare Parts
Source:Endress+Hauserwebsite public information
Case Studies
市政污水处理污水处理厂 · 罐区应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对罐区的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的罐区,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 罐区应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对罐区的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的罐区,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 罐区应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对罐区的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的罐区,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 罐区应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对罐区的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的罐区,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。