电导率传感器
Technical Data
CompareConductivity
| Measuring Principle | Inductive |
| Application | Food, beverage and pharmaceutical industries, biotechnology, dairies, breweries |
| Characteristic | Specifically intended for use in hygienic applications and especially suitable for following applications: Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring |
| Measuring range | 100 µS/cm to 2000 mS/cm Cell constant k: 6.3 1/cm |
| Measuring principle | Inductive conductivity measurement |
| Design | Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications |
| Material | In contact with medium: virgin PEEK |
| Process temperature | -10 °C to 125 °C (14 °F to 257 °F) Sterilization: 150 °C at 6 bar abs for max. 60 min (302 °F at 87 psi abs for max. 60 min) |
| Process pressure | 13 bar abs up to 90 °C (188.5 psi abs up to 194 °F) 9 bar at 125 °C (130.5 psi abs at 257 °F) |
| Temperature sensor | Pt1000 (Class A according to IEC 60751) |
| Connection | Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50 |
| Ingress protection | IP68 / NEMA type 6P |
| Certificates, declarations and approvals | Surface roughness test ISO4287/Ra (≤ 0,8 µm) Bio reactivity test USP Class VI US Food Contact Materials FDA CFR 21 EU Food Contact Materials (EG) 1935/2004 CN Food Contact Materials GB 4806 EHEDG EL Class I, 3-A |
The Indumax CLS54D inductive conductivity sensor ensures that all products and processes meet the strictest hygiene and sterility requirements. It combines high performance with a unique hygienic design to guarantee the highest product quality and maximum safety. Based on Memosens digital technology, the Indumax CLS54D combines simple operation with maximum process and data integration; it is corrosion- and moisture-resistant, can be laboratory-calibrated and facilitates predictive maintenance.
Advantages
Unique hygienic design prevents contamination
All approvals for hygienic and sterile applications, compliant with EG 2023/2006 and 1935/2004
Food-grade PEEK body with seamless, joint-free connection
Biocompatibility approval compliant with USP Cl. VI
Suitable for CIP and SIP
Convenient maintenance strategy with data and sensor management via Memobase Plus
Reliable measurement based on connection monitoring and EMC protection
Areas of application
The Indumax CLS54D can be used for toroidal conductivity measurement in the food and beverage and life sciences sectors, e.g.:
Phase separation between medium/medium and medium/water in piping systems
CIP process control in return channels
Concentration control during CIP cleaning agent regeneration
Medium monitoring in piping systems, filling plants and quality assurance systems
Leak monitoring
Unique hygienic design compliant with EHEDG and 3-A
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
A
Source:Endress+Hauserwebsite public information
Case Studies
市政污水处理污水处理厂 · 电导率应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导率的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 电导率应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导率的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 电导率应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导率的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 电导率应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导率的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。