Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

亚硝酸盐分析仪 CA80NO

亚硝酸盐分析仪  CA80NO

亚硝酸盐分析仪 CA80NO

Liquiline System CA80NO offers precise, regulation-compliant online measurement of nitrite. It supports you in meeting the specified limits in drinking water, mineral water or food production. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating and maintenance costs. Advanced diagnostics with remote access ensure process safety.
Compare

Analyser

Measuring Principle Colorimetric
Characteristic Process analyzer for Nitrite in potable water
Size Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in
Design Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel
Process temperature 4 to 40 °C (39 to 104 °F)
Ambient temperature 5 to 40 °C (41 to 104 °F)
Outdoor version: - 20 to 40 °C (-4 to 104 °F)
Process pressure At atmospheric pressure, < 0.2 bar absolute
Sample flow rate Min. 5 ml/min (0.17 fl.oz/min)
Consistency of the sample Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized
Specials Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Optional cooling module for standard solution
2 channel version optional
User-definable measuring ranges
Modular design for easily extensible functionality
Application Limit value monitoring of nitrite for potable water and mineral water applications
Power supply 100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz
Output / communication 2x 0/4 to 20 mA
Modbus RS485/TCP (optional)
Ethernet (optional)
Alarmrelay
Input 1 or 2 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)
Measuring range 10 to 500 µg/l NO2-N
0.2 to 3.0 mg/l NO2-N
0.1 to 1.0 mg/l NO2-N
0.1 to 1.0 mg/l with dilution function to maximum 5 to 50 mg/l NO2-N
Consumables Reagents and standard solutions CY80NO as well as cleaner CY800 are necessary for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800

The Liquiline System CA80NO performs compliant, high-precision online nitrite measurement, helping you meet the limit value requirements in drinking water, mineral water or food production. Like all Liquiline System analyzers, it can connect up to four plug-and-play Memosens sensors, minimizing installation costs. Automatic calibration and cleaning with low reagent consumption reduce operating and maintenance costs. Advanced diagnostics with remote access ensure process safety.

 

Advantages

Based on the standard colorimetric measuring principle - naphthylamine method - compliant with ISO 6777 and DIN EN 26777, ensuring compatibility with laboratory measurement results

Automatic calibration and cleaning reduce operating and maintenance costs

Simple maintenance: no tools required

Advanced diagnostics with remote access increase process safety

Memosens technology with a user-friendly interface enables convenient, plug-and-play commissioning

Functional upgrades, even to a complete measuring station, require only the simple addition of modules and connection of Memosens sensors, reducing installation costs

 

Areas of application

The Liquiline System CA80CR helps you improve process environmental performance:

 

Drinking water

Mineral water

Raw water in food production

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

Source:Endress+Hauserwebsite public information

市政污水处理

市政污水处理污水处理厂 · EH-ONLINE应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · EH-ONLINE应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · EH-ONLINE应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · EH-ONLINE应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;