Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CLS82E 电导率传感器

CLS82E  电导率传感器

电导率传感器

Configurable Models 1 models
Memosens CLS82E is a high-end, hygienic sensor for applications with widely varying conductivity values. It enables reliable monitoring of core processes as well as final rinse with only one sensor. FDA compliance and a small, compact design ensure the perfect fit to your processes. With Memosens 2.0 digital technology, CLS82E allows for extended storage of process and sensor data facilitating lab calibration and predictive maintenance and providing the perfect basis for enhanced IIoT services.

Memosens CLS82E is a high-end hygienic sensor suitable for applications requiring a wide conductivity range. A single sensor reliably monitors critical process steps and the final rinsing step. It is FDA-certified and its small, compact design adapts perfectly to the actual process. CLS82E uses Memosens 2.0 digital technology, supports extended data storage, saves calibration and process parameters and allows laboratory pre-calibration of the sensor, providing the perfect basis for implementing predictive maintenance and advancing IIoT technology.

Advantages
Hygienic design with material certifications, EHEDG tested, 3-A and FDA approvals ensure GMP compliance. The sensor withstands high-temperature disinfection and autoclaving.
With Memosens technology, the electrode features a dedicated buildup detection function to keep the measuring loop safe at all times.
Wide measuring range; a single sensor reliably monitors critical process steps and the final rinsing step, saving costs.
The sensor is small and compact and can be installed in small-diameter pipes and confined spaces for measurement.
The quality certificate indicates the electrode's cell constant, precisely adjusted to obtain high-precision measurement results.
Non-contact inductive signal transmission provides high process and data integrity.
Supports IIoT: Memosens 2.0 supports extended data storage, saves calibration and process parameters for better trend identification, and is the perfect basis for implementing predictive maintenance and advancing IIoT technology.

Application
The Memosens CLS82E conductivity sensor has a wide range of applications:
Phase separation
Downstream processing
Fermentation
Chromatography
Ultrafiltration
Final rinsing step in pharmaceutical production
With international explosion protection approvals such as ATEX, FM, CSA and NEPSI, the digital sensor can be used in hazardous areas.

 

E+H Product Configurator

Please enter the product model to configure

   

Product comparison

Please enter the product models to compare in the boxes below (max. three products)

 

   

Technical documentation

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

Source:Endress+Hauserwebsite public information

Compare

Conductivity

Measuring Principle Conductive
Application Phase seperation, chromotography, fermentation
CIP monitoring in small pipes
Ultrafiltration
Final rinse
Characteristic Conductivity sensor with a broad measurement range for all hygienic applications with advanced requirements to process safety
Measuring range 1 µS/cm to 500 mS/cm
Measuring principle Hygienic 4-electrode conductivity sensor
Design Certified hygienic design with FDA compliant materials, 3-A and EHEDG certified, available as 120 mm sensor with PG13.5 and in many other standard process connections
Material Process connection: stainless steel 1.4435 (316L)
Sensor element: platinum and ceramic
Dimension Sensor diameter: 12 mm (0.47 inch)
Electrode length: depending on process connection
Process temperature -5 to 120 °C (23 to 248 °F)
Sterilization: max. 140 °C at 6 bar for max. 45 min
(Max. 284 °F at 87 psi for max. 45 min)
Process pressure 17 bar abs at 20 °C (247 psi at 68 °F)
9 bar abs at 120 °C (131 psi at 248 °F)
Temperature sensor Pt1000
Ex certification ATEX, NEPSI, CSA, IECE, EAC Ex, INMETRO
Connection Clamp 1,5", Clamp 2", Varivent F DN25,Varivent N DN40-DN125, BioControl DN25, PG13,5, DN25 standard/40mm, DN25 B.Braun port/65mm, Threat G1", Thread NPT 1"
Sensor connection: Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP 68 / NEMA Type 6P
Certificates, declarations and approvals Inspection certificate 3.1, EN10204
Surface roughness test ISO4287/Ra (≤ 0,38 µm)
Conformity to cGMP derived requirements
ASME BPE
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I, 3-A
Model Name
CLS82E-AAGA30 电导率传感器
市政污水处理

市政污水处理污水处理厂 · 电导率应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 电导率应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 电导率应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 电导率应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。