Technical Data
CompareDensity
| Measuring Principle | Coriolis |
| Product Headline | Flowmeter with minimized total cost of ownership, as remote version with up to 4 I/Os. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Density/Concentration
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership, as remote version with up to 4 I/Os. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –40 to +150 °C (–40 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L) |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Gas
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership, as remote version with up to 4 I/Os. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –40 to +150 °C (–40 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L) |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Liquids
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership, as remote version with up to 4 I/Os. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –40 to +150 °C (–40 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L) |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Steam
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership, as remote version with up to 4 I/Os. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
The Promass E is robust and is an economical solution for long-term use in high-precision liquid and gas measurement in various standard applications across different industries. Combined with the innovative remote transmitter, the Promass E 500 offers maximum installation flexibility and the highest operational safety even under demanding conditions. Heartbeat Technology ensures compliance at all times and guarantees process safety.
Benefits
Economical: versatile instrument; preferred alternative to conventional volumetric flowmeters
Fewer process measuring points: multivariable measurement (flow, density, temperature)
Space-saving installation: no inlet/outlet straight run requirement
Complete view of process and diagnostic information: various user-configurable input/output combinations and fieldbuses
Reduced complexity and diversity: user-configurable input/output functions
Integrated verification: built-in Heartbeat Technology
Applications
The measuring principle is unaffected by the physical properties of the fluid (e.g. viscosity and density).
High-precision measurement of liquids and gases in standard applications, with broad applicability.
Device features
Compact dual measuring tube sensor
Medium temperature: max. +150 °C (+302 °F)
Process pressure: max. 100 bar (1450 psi)
Remote version with up to 4 inputs/outputs
Backlit display, touch key operation and WLAN access
Sensor and transmitter connected by standard cable
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source: Endress+Hauserpublic information from the website
Case Studies
市政污水处理污水处理厂 · 质量流量计应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 质量流量计应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 质量流量计应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 质量流量计应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。