Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

FMR540 高精度雷达液位计

FMR540 高精度雷达液位计

高精度雷达液位计

Micropilot FMR540 is used for custody transfer and inventory control applications with NMi- and PTB-approvals and meets the requirements according to OIML R85 and API 3.1B. FMR540 with parabolic antenna is particularly suited for free space applications up to 40m and with horn antenna for free space applications that disallow the use of a parabolic antenna due to tank/nozzle geometry. Cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supply.

The Micropilot FMR540 is approved by NMi and PTB, can be used for custody transfer and inventory control, and meets the relevant requirements of the R85 and API 3.1B standards. With a parabolic antenna, the FMR540 is especially suitable for measurement in any space within 40 m; with a horn antenna, the FMR540 can be used where the shape of the tank/installation nozzle prevents the use of a parabolic antenna. The Micropilot FMR540 uses a four-wire system, HART and 24 VDC intrinsically safe power supply, and is economical and easy to install.

 

Benefits

Accuracy better than 1 mm

Custody transfer applications with national certifications (NMi and PTB)

The instrument can be used standalone or integrated with a tank level measurement system via the NRF590 tank side indicator

Four-wire, HART and 24 V DC intrinsically safe power supply, cost-effective and easy to install.

Angle adjustment device compensates for flange inclination

Simple on-site operation via menu-driven alphanumeric display module

Convenient instrument commissioning, documentation and fault diagnosis using the FieldCare operating software

 

Application areas

The parabolic antenna is suitable for use in any space with a range of up to 40 m, providing highly focused measurement where the nozzle is close to the tank wall, 4"/diameter 100; the horn antenna is suitable for use in any space.

 

Process connection: flange

Temperature range: -40 to +200 °C (-40 to +392 °F)

Pressure range: vacuum to +16 bar (vacuum to +232 psi)

Maximum measuring range: 40 m (131 ft)

Accuracy: less than ±1 mm

K-band: 26 GHz

International explosion protection approval, custody transfer approval, WHG overflow protection, SIL

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Compare

Continuous / Liquids

Measuring Principle Level radar
Characteristic / Application Horn antenna:
High precision measurement for for storage tanks up to 20 m (65ft)
Parabolic antenna:
High precision measurement for free space applications up to 40 m (131 ft)
Supply / Communication 4-wire (HART)
Frequency K-band (~26 GHz)
Accuracy +/- 1 mm
Ambient temperature Standard:
-40°C...80°C
(-40°F...176°F)
For calibration to regulatory standards:
-25°C...60°C
(-13°F...131°F)
Process temperature -40°C...200°C
(-40°F...392°F)
Process pressure / max. overpressure limit Horn: Vacuum...16 bar (232 psi)
Parabolic: Vacuum...6 bar (87 psi)
Use of UNIflange: Vacuum...1 bar (14.5 psi)
Main wetted parts 316L
Process connection Horn Antenna: DN100, DN150 Flange
UNIFlange DN150, DN200, DN250
Parabolic antenna: UNIflange with Top Target
positioner DN200, DN250
For dk value < 1.9, contact Endress+Hauser
Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, CSA, IEC Ex, NEPSI
Application limits Maximum measuring range is dependent on the tank form and/or application
Strong condensate or build-up formation
FMR53x
Existing stilling wells with non-ideal measuring conditions
FMR532
市政污水处理

市政污水处理污水处理厂 · 雷达应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对雷达的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的雷达,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 雷达应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对雷达的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的雷达,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 雷达应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对雷达的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的雷达,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 雷达应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对雷达的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的雷达,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。