Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

11375Z 电导式液位计

11375Z 电导式液位计

电导式液位计

The 11375Z is a cost-effective and reliable solution for conductive point level detection in process or storage tanks for all kinds of liquids.

The economical 11375Z probe can be used for limit detection of various liquids in processes and tanks.

 

Advantages

A cooler can be fitted when measuring high-temperature liquids (e.g. 100°C)

Probe length can be shortened

WHG (German Water Resources Act) + ATEX II 1/2 G approval

Can be connected to the independent FTW325 switching unit

Linear monitoring, safe and reliable

No moving parts in the tank, no wear, long service life, reliable function

Economical probe for conductive liquids

 

Areas of application

For limit detection of various liquids in processes or tanks:

 

Conductivity of 0.02mS/cm

Temperature range 40~+200°C

Pressure up to 50bar; linear monitoring and overflow protection in explosion Zone 0, upper/lower limit detection in tanks, protection of pipeline pumps, and two-point control

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Compare

Point Level / Liquids

Measuring Principle Conductive
Characteristic / Application One rod probe for high temperature and high pressure. corrosion resistant
Supply / Communication Relay
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 135 °C
(-40 °F ... 275 °F)
Process pressure / max. overpressure limit Vacuum ... 50 bar
(Vacuum ... 725 psi)
Min. conductivity of medium 20 µS/cm
Main wetted parts PTFE, 316TI
Process connection G1/2
Sensor length 0.05m ... 2m
(2" ... 79")
Communication Relay
Certificates / Approvals ATEX
Components Transmitter: FTW325
Application limits observe min. medium conductivity
市政污水处理

市政污水处理污水处理厂 · 电导式应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导式的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 电导式应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导式的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 电导式应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导式的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 电导式应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导式的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。