The Liquipoint FTW32 offers simple and safe point level detection in conductive liquids. It offers numerous measuring possibilities due to multipoint detection (up to 5 rods).
Compare

Point Level / Liquids

Measuring Principle Conductive
Characteristic / Application Compact rope probe with multi point detection possible up to 5 switch points. Simple rope shortening possible
Supply / Communication DC PNP 10,8V ... 45V
Relay 20V ... 230V AC
Relay 20V ... 55V DC
Ambient temperature -40 °C ... 70 °C
(-40 °F ... 158 °F)
Process temperature -40 °C ... 70 °C
(-40 °F ... 158 °F)
Process pressure / max. overpressure limit Vacuum ... 10 bar
(Vacuum ... 145 psi)
Min. conductivity of medium 10 µS/cm
Main wetted parts 316L, FEP, PPS
Max. tensile strength 500 N
Process connection G 1 1/2
NPT1 1/2"
Sensor length 0.25m ... 15m
(10" ... 590")
Communication DC PNP
Relay
Certificates / Approvals ATEX, EAC Ex
Safety approvals Leakage Detection
Components Transmitter: FTW325
Application limits Observe min. medium conductivity

The Liquipoint FTW32 can be used for simple and safe limit detection of conductive liquids. The multi-point detection function (up to 5 rods) extends the measuring range of the Liquipoint FTW32.

 

Advantages

One probe can be used for up to five limit detection points

Two-point control with upper and lower limit detection

Flexible use:

1. Cable probe with plug-in electronics and selectable 2 or 3 transistor or relay outputs;

2. Connection to a separate transmitter power supply unit

No calibration required; suitable for common conductive liquid measurement

No moving parts: - long service life - no wear and clogging, reliable operation

Four measuring ranges can be set: 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ

Economical probe for conductive liquids

 

Areas of application

The Liquipoint T sensor is suitable for limit detection of conductive liquids (10μS/cm). Depending on the number of measuring points (up to 5 cable probes), tasks such as overflow protection, dry-running protection, two-point pump control and multi-point detection can be performed via existing process connections.

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

市政污水处理

市政污水处理污水处理厂 · 电导式应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导式的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 电导式应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导式的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 电导式应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导式的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 电导式应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导式的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。