The Nivotester FTW325 level limit switch uses an intrinsically safe signal circuit and can be connected to conductive sensors. Its compact housing is convenient for installation on a standard DIN rail in an instrument cabinet.
Advantages
The limit switch is low-cost and suitable for conductive liquids
Linear sensor monitoring
Adjustable sensitivity range
ATEX, FM and CSA certification
With the intrinsically safe signal circuit EEx ia IIC, the sensor can be used in hazardous areas.
Measuring range up to 200 kΩ
The alarm relay can be converted into a changeover relay (SPDT)
Application
The limit switch can be used for liquid detection in tanks; ATEX II (1) GD EEx ia IIC is suitable for hazardous areas. Equipped with overfill protection, it is used for tank measurement of flammable or non-flammable water-polluting liquids. For pumps, it is equipped with dry-run protection. Used together with the Nivotester, it provides two-point control and point level detection.
E+H Product Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the boxes below (max. three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserwebsite public information
Technical Data
ComparePoint Level / Liquids
| Measuring Principle | Conductive |
| Characteristic / Application | 2-channel level measurement device, level limit, switch delay, two-point control |
| Supply / Communication | 85V ... 253V AC 20V ... 30V AC 20V ... 60V DC |
| Ambient temperature | -20 °C ... 60 °C (-4 °F ... 140 °F) |
| Min. density of medium | min. 10 uS |
| Communication | 2 relays SPDT/DPDT |
| Certificates / Approvals | ATEX, FM, CSA, NEPSI, EAC |
| Safety approvals | Overfill protection WHG |
Related Models
| Model | Name |
|---|---|
| FTW325-12A1A | 电导式限位检测 |
| FTW325-A2A1A | 电导式限位检测 |
| FTW325-A2B1A | 电导式限位检测 |
| FTW325-B2A1A | 电导式限位检测 |
| FTW325-B2B1A | 电导式限位检测 |
| FTW325-C2A1A | 电导式限位检测 |
| FTW325-C2B1A | 电导式限位检测 |
Case Studies
市政污水处理污水处理厂 · 电导式应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导式的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 电导式应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导式的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 电导式应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导式的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 电导式应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导式的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导式,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。