Cubemass is the proven sensor for the measurement of smallest flow rates in skids, test rigs and industrial robotics, e.g. in applications like lacquering or surface finishing. Neither high pressure nor alternating flow conditions compromise its accuracy. Equipment manufacturers value Cubemass as compact Coriolis sensor.

Advantages
Cubemass can measure multiple process variables simultaneously (mass/density/temperature) in a wide range of processes.
FieldCare for on-site diagnostics
Extremely low energy consumption

Application areas
Coriolis measuring principle operates independently of the physical fluid properties.
Fluid temperature up to + 200°C(392°F +)
Process pressure up to 400bar(5800 psi)
Mass flow measurement up to 1000 kg/h (36.75 lb/min)
Hazardous area application approvals
ATEX, NEC/CEC, NEPSI
Common process connection control systems
Modbus RS485

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

Compare

Gas

Measuring Principle Coriolis
Product headline Compact sensor for smallest quantities with easy system integration.
Measuring accurately smallest quantities of liquids and gases.
Sensor features Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor.
Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
Transmitter features Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
Robust transmitter housing. Modbus RS485. Pulse output.
Nominal diameter range DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3
Measuring range 0 to 1000 kg/h (0 to 37 lb/min)
Max. process pressure PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium temperature range –50 to +200 °C (–58 to +392 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure
Display/Operation No local operation
Configuration via operating tools possible
Outputs Pulse/frequency/switch output (passive), phase‐shifted pulse
Inputs None
Digital communication Modbus RS485
Power supply DC 10 to 30 V
AC 20 to 28 V
Hazardous area approvals ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
CRN

Liquids

Measuring Principle Coriolis
Product headline Compact sensor for smallest quantities with easy system integration.
Measuring accurately smallest quantities of liquids and gases.
Sensor features Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor.
Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
Transmitter features Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
Robust transmitter housing. Modbus RS485. Pulse output.
Nominal diameter range DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3
Measuring range 0 to 1000 kg/h (0 to 37 lb/min)
Max. process pressure PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium temperature range –50 to +200 °C (–58 to +392 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure
Display/Operation No local operation
Configuration via operating tools possible
Outputs Pulse/frequency/switch output (passive), phase‐shifted pulse
Inputs None
Digital communication Modbus RS485
Power supply DC 10 to 30 V
AC 20 to 28 V
Hazardous area approvals ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
CRN
Metrological approvals and certificates 3.1 material
Pressure approvals and certificates CRN
市政污水处理

市政污水处理污水处理厂 · 质量流量计应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 质量流量计应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 质量流量计应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 质量流量计应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。